Loading...
HomeMy WebLinkAbout[W2] Transportation Corridor OverlayPlanning Commission Agenda Item W 2 I7'Y OF ST. J(,)S wH MEETING DATE: AGENDA ITEM: SUBMITTED BY: STAFF RECOMMENDATION: May 3, 2010 Ordinance Discussion — Transportation Corridor Overlay Administration PREVIOUS PLANNING COMMISSION ACTION: At the last Planning Commission meeting the Ordinance referred to as the Transportation Corridor Overlay was discussed as it related to the request of Tom Borresch and general comments concerning applicability. It was mentioned that the development in 2009 is not consistent with the Ordinance. BACKGROUND INFORMATION: Included in the material is the review of the 2009 projects that relate to the Corridor and the detail that illustrates compliance with the Ordinance. There appears to be some confusion as to the requirements. The Overlay District applies to parcels within 300 feet of the ROW and the setback for building has to be 100 feet from the ROW, not the property line. Following is a map of the north side of CSAH 75 showing both the applicable properties and the 100 foot setback line. The Planning Commission requested the opportunity to discuss in a workshop setting the Ordinance in detail. This meeting will take place immediately following the regular Planning Commission meeting and will be held in the conference room. ATTACHMENTS: Transportation Corridor Overlay Ordinance 52. 21 ....... ............................... W2:1 -6 Illustration of County Road 75 Transportation Corridor Overlay District W2:7 -8 2010 [04] Apr 28 MDG Memo .......................................... ............................... W2:9 -12 2010 [03] Mar 26 MDG Memo ......................................... ............................... W2:13 -21 Definition of Viewshed ...................................................... ............................... W2:22 REQUESTED PLANNING COMMISSION ACTION: Provide direction to staff ORDINANCE 52 — ZONING ORDINANCE Section 52.21: TRANSPORTATION CORRIDOR OVERLAY DISTRICT SITE AND DESIGN STANDARDS Subd. 1: Intent. a) This district is intended to protect and promote the health, safety and general welfare of the public; to enhance the visual appearance of the corridor; to protect and promote the appearance, character and economic values along the corridor and the surrounding neighborhoods. b) This district is furthermore intended to maintain the long -term function of arterial and collector roadways; to limit access and the number of conflict points; to promote vehicular circulation; and to promote prevention or reduction of traffic congestion and danger in the public streets. Subd.2: Scone. a) The Transportation Corridor Overlay District shall be defined as follows: 1. CSAH 75 Corridor: A. West of South Fork of Watab River: areas within 300 feet from the nearest edge of the CSAH 75 right of way. B. CSAH 75 West of 20th Avenue: areas within 300 feet from the nearest edge of the CSAH 75 right of way. 2. 20th Avenue Corridor: A. South of CSAH 75: areas within 300 feet from the nearest edge of the 20th Avenue right of way. B. North of CSAH 75: areas within 300 feet from the nearest edge of the 20th Avenue right of way. CSAH 2 /CSAH 3 Corridor: A. South of CSAH 75: areas within 300 feet from the nearest edge of the FUTURE CSAH 2 right of way. B. North of CSAH 75: areas within 300 feet from the nearest edge of the CSAH 2 /CSAH 3 right of way. W2:1 ORDINANCE 52 — ZONING ORDINANCE 4. 1 -94 Corridor: A. 500 feet from the nearest edge of the 1 -94 right of way. Subd. 3: Exemptions. Single and two - family residential uses shall not be subject to the standards of the transportation corridor overlay district. However, at such time that a single or two - family residential use is to be converted to another use it will be subject to the standards of the transportation corridor overlay district. Subd. 4: Uses Allowed. Permitted, conditional, interim and accessory uses allowed within the transportation corridor overlay district shall be the same uses those allowed in the applicable underlying zoning district(s). Subd. 5: Setbacks, site coverage, building height, building requirements contained within the applicable underlying zoning district shall apply. In addition the following standards shall be observed. All buildings shall maintain a minimum setback of one hundred (100) feet from the road right -of -way limit. Corner lots shall maintain two front setbacks. Subd. 6: Parking_ Standards. The following standards shall be in addition to those required within Section 84 of this ordinance relating to off - street parking and loading. Where standards conflict the most restrictive standard shall apply. a) Parking areas shall be designed and located so as to have minimal visual impact along transportation corridors. Therefore, all parking areas shall be constructed in the rear or side yards, unless specifically permitted in the front yard by the Planning Commission. When permitted in the front yard, additional landscaping and buffering may be required by the Planning Commission to minimize visual impact. No parking will be allowed within a fifty (50) foot setback from the nearest external boundary of the applicable transportation corridor right -of -way limit. b) Where a development application covers land located adjacent to an existing parking lot used for similar purposes, a vehicular connection between the parking lots shall be provided wherever possible. For development applications adjacent to vacant properties, the site shall be designed and constructed to provide for a future connection. C) Parking lot landscaping. All development sites shall landscape an area equivalent to fifteen (15) percent of the total area of the required parking lot. Said required landscaping shall be employed within the subject parking lot and adjacent to walkways within and leading to /from the subject parking lot. Subd. 7: Sign Standards. The following standards shall be in addition to those required within Section 52.11 of this ordinance relating to signs. Where standards conflict the most restrictive standard shall apply. W2:2 ORDINANCE 52 — ZONING ORDINANCE a) Free - standing signs shall not be placed nearer than twenty (20) feet from the nearest edge of the transportation corridor right -of -way. b) Free - standing signs within the required landscaped greenway shall be designed in a manner complementary to the landscaped greenway. c) Free- standing identification signs shall have a low - profile design not more than eight (8) feet in height and shall be designed to complement and reflect the architecture of the building. Subd. 8: Site Design Standards. a) Viewsheds. 1. Viewsheds shall be defined as the area between two separate locations wherein an uninterrupted view of each point is maintained. The viewshed in the transportation corridor overlay district shall at a minimum correspond to a forty (40) foot landscaped greenway as measured from the nearest edge of the applicable right of way. 2. Viewsheds shall be considered in all development proposal applications within the transportation corridor overlay district. 3. Development shall be designed to minimize the visual intrusion of all buildings, structures, and landscaping in the viewshed. b) Outside storage / displU of goods. Outside storage or display of goods except automotive and similar large item sales shall be completely screened from the view of the corridor roadway by the employment of a vegetative buffer. This standard is in addition to those required within the underlying zoning classification and Section 52.10, Subd. 10 of this ordinance relating to outdoor storage. Where standards conflict the most restrictive standard shall apply. C) Utilities. Utility lines, including electric, cable and telephone, to serve the development project shall be installed underground. All junction and access boxes shall be screened. All utility pad fixtures, meter boxes, etc. shall be shown on the site plan and integrated with the architectural elements of the site. In redeveloping areas within the transportation corridor overlay placement of utility lines underground is highly encouraged. d) Fences. 1. This standard is in addition to those in Section of this ordinance relating to fencing. Where standards conflict the most restrictive standard shall apply. W2:3 ORDINANCE 52 — ZONING ORDINANCE 2. Fences exceeding four (4) feet in height shall be located in the side and rear yards only. Chain link fences, including those with slats are prohibited when visible from the public right -of -way. 4. No fence shall be permitted in the front yard, except that those provided to enhance the visual appearance of the site /landscaping plan may be allowed provided they do not exceed two feet in height and are of a reasonable linear length. e) Mechanical equipment. Mechanical equipment shall be shielded and screened from the public view and designed to be perceived as an integral part of the building. f) Street tree landscaping. In all instances where commercial and /or multi - family residential districts are adjacent to any public street, street tree /landscaping will be required as approved by the City. Subd. 9: Building Layout/Design. a) Integrated development. All buildings within the property shall be developed as a cohesive entity, ensuring that building placement, architectural treatment, vehicular and pedestrian circulation and other development elements work together functionally and aesthetically. Architectural treatment shall be designed so that all building facades of the same building (whether front, side, or rear) that are visible from the public right -of -way, shall consist of similar architectural treatment in terms of materials, quality, appearance and detail. b) Clustering. Buildings shall be clustered together to preserve natural and landscape open areas along the transportation corridor. Buildings shall be arranged in a manner that creates well - defined open space that is viewable from the traveled portion of the corridor. C) Architectural Appearance /Scale. New buildings shall have generally complex exterior forms, including design components such as windows, doors, and changes in roof and facade orientation. Large flat expanses of featureless exterior wall shall be avoided. The treatment of buildings shall include vertical architectural treatment at least every 25 -30 feet to break down the scale of the building into smaller components. 2. Orientation. Building facades and entrances should be oriented in a manner toward the primary means of vehicular access. W2:4 ORDINANCE 52 — ZONING ORDINANCE 3. Scale and proportion. New construction should relate to the dominant proportions of buildings and streetscape in the immediate area. The ratio of height to width and the ratio of mass (building) to void (openings) should be balanced. 4. Architectural details shall continue on all facades visible from the public right -of -way. 5. Any facade with a blank wall shall be screened with vegetative treatments and /or the installation faux architectural treatments (e.g. fenestrations) so as to break up the mass and bulk of the facade in a manner fitting the intent of this section. d) Materials. Building materials shall be typical of those prevalent in commercial areas, including, but not limited to, stucco, brick, architectural block, decorative masonry, non - reflective glass and similar materials. Architectural metal may be used for a portion of facades facing public rights of way but shall not be the dominant material employed with windows and doors being excluded from this calculation. e) Color. The permanent color of building materials (to be left unpainted) shall resemble earthen tones prevalent in nature. Showy and striking colors shall be avoided. f) Lighting: All outdoor lighting fixtures shall be down- directed, with light trespass not to exceed 0.5 foot - candles at the property line. 2. All island canopy ceiling fixtures shall be recessed. Whenever possible commercial lighting should be reduced in volume /intensity when said commercial facilities are not open for business. Subd. 10: Veizetative Screening/Buffers. a) This standard is in addition to those in Section 52.12, Subd. 3 of this ordinance relating to landscaping. Where standards conflict the most restrictive standard shall apply. b) Any required vegetative /planting screen shall be designed, planted and maintained in accordance with a landscaping plan approved by the Zoning Administrator. C) The painting screen shall provide an effective buffer between the area to be screened and the adjoining roadway or commercial /industrial development. W2:5 ORDINANCE 52 — ZONING ORDINANCE d) The planting screen may be comprised of previously existing vegetation (provided that the majority of such existing vegetation is trees), new plantings or any combination of existing vegetation and new plantings. When complete, the vegetation and plantings shall provide a dense year -round screen satisfying the purpose and intent of this section. e) The planting screen may consist of a mixture of deciduous and evergreen trees and/or shrubs or a planting of evergreen trees and /or shrubs. f) The planting screen shall be subject to on -site inspection by the City which, if necessary, may prescribe that additional plantings be made in order to satisfy the standards set out herein. g) The property owner shall maintain vegetative /planting screening in accordance with the approved landscaping plan and to abide by requirements for any additional plantings. h) Vegetative buffering. In all instances where commercial and /or multi- family residential districts are adjacent to single - family residential districts, and in all instances where commercial districts are adjacent to multi - family residential districts, there shall be established within the commercial and /or multi - family district, as applicable, a screened yard of vegetative buffering between the districts. The arrangement and spacing of the vegetative buffer shall be provided in such a manner as to effectively screen the activities of the subject lot. It shall generally be provided along the property line, unless topographic or other considerations would make it more effective if located back from the property line. W2:6 C 0 0 0 Q W 0 c- 0 W Q) X w / U O / w 0 V J / / / w Li w V) Q O O O N 0 1-f T is map is neither a legally recorded map nor a survey map and is not intended to be used as one. 4 t- ► r" . p map is a compilation of records, information, 1 and data gathered from various sources and is to lip. s, - - a -,. be used for reference purposes only. SEH does not that - z warrant Geographic Information � $� I "" i ,,� P .- I . Data iser or free, and SEH does of rep represent hlS at EA# the GIS Data can be used for navigational, tracking, or any other purpose requiring exacting measurement of distance or direction or precision in the depiction of Aw. +,,° geographic features. - _, I JASMINE �. �. ga The location of future roadways are subject to change and not necessarily indicative of preferred alternatives. . F , :� • t �, `` � _ - �,;' I � — ,�' LANE Grp oe do ef # IRIS k I r s i HICKORY ST. E. CKORY RIVE ° + ■- I T" D � z ' •. , -, I f I + 444 - i - -- r HACKBERRY A ti 4. P > s 4- . LU ry a t ;x .• I Qs '~ _ F ■ � G UMTRE E w E U � J > M TRH E ST. Z Z E. w f C Li , w r° Z 7 i L � Y o = a 11 r - rr i I * I ' 1� t cr FIR S � 4r IF - -- - - -- rt it———— — — — — —— C" — — — —— — — — — — —— —r —— — — —— Q — — — — — — —— — 1 FIR ST. E. • ,� - - - -- -- - - - - -- - - - - - - - f r, � s. � ELM ST. W EQA 5T. E:.. La El M ST rZ r P „ Atc Ta - - - -- CITY LIMITS N N ' DATE ST. W. DATE ST. E. R ORTHE N p SETBACK I 300' TRANSPORTATION I _ CEDAR ST E CORRIDOR OVERLAY Ot DISTRICT BOUNDARY ' I - A a rn I ` • f-11 I i rn I a - - ,. ' - ` \ 5 I r a ST. Lq J - '2 > a BIRCH ST. W. - �,- y41116 i1 k o d I T,. r d I . - H W z z UJ 0 250 500 UJ w > I I t _ ,.. ABLE. - LF yr -^ �? l ,� I rn, w I ABLE ST. E. qlT IL Ir { r, Cl COUNTY ROAD 75 TRANSPORTATION CORRIDOR OVERLAY DISTRICT (NORTH SIDE) SEH ST. JOSEPH, MINNESOTA , u6pvogo»odcuoil \q /4063\611gryx3 \POD \[96801 \30f1S \S\ld \ :d 3113 H3S M 9Z:80A1 OIOZ /Of /f ,;, a °o cr w O02 N z Za 3 QUCO cr C0 Zg LO W "o 0 Q O Er z O U � W &JmvhA MUNICIPAL DEVELOPMENT GROUP, INC. DATE: April 28, 2010 MEMO TO: Judy Weyrens, City Administrator FROM: Cynthia Smith - Strack, Municipal Development Group RE: Coborn's Site Plan and Transportation Overlay District Background Following per your request is a review of the Coborn's site plan as it relates to the Transportation Overlay District. Please note using Dataview I have scaled the distance from the CSAH 75 ROW to the edge of the property line at over 100' due to the presence of the rail /trail ROW. The attached drawing illustrates the distance of said property from the CSAH 75 right of way. Since the subject parcel is within 300' from the CSAH 75 ROW it is subject to standards contained in Section 52.21 "Transportation Corridor Overlay District ". It is noted that the standards pertaining to the Transportation Corridor Overlay District while they apply to the subject parcel are concentrated on enhancing the visual appearance of the corridor and protecting /promoting the appearance, character, and economic value of the corridor. As such most standards related to areas closest to the edge of the CSAH 75 ROW. Since the subject property is greater than 100' from the edge of the CSAH 75 ROW (at the property line) and the structure and associated parking are setback over 30' from the property line most standards are met on face -value without a presumed need for further review. Section 52.21 Transportation Corridor Overlay District Section 52.21, Transportation Corridor Overlay District is superimposed on the underlying zoning classification (132 Highway 75 Business District). Section 52.21 is intended to enhance the visual appearance of the corridor and to protect and promote the appearance, character, and economic values along the corridor and the surrounding neighborhoods. The district is furthermore intended to maintain the long -term function of arterial and collector roadways. Additional Within the Transportation Corridor Overlay, all buildings must maintain Setback: a minimum setback of forty (40) feet from the CSAH 75 right -of -way and a front yard setback of 100' from the ROW. The proposed structure's 'future addition' is setback more than 100' feet from the property line which is setback more than 100' from the CSAH 75 ROW line. The property does not abut CSAH 75 right of way, but rather the Wobegon Trail /MnDOT Railway corridor. The trail corridor right of way exceeds 100' in width, therefore proposed structure setbacks conform to requirements under Section 52.21 of the Zoning Ordinance. Parkin Additional parking lot standards apply within the Transportation Corridor Standards: Overlay, said standards are in addition to those required under Section 52.10 of the Zoning Ordinance. Specifically, A. Parking areas shall be designed and located so as to have minimal visual impact along transportation corridors. Lots with rear -yards abutting transportation corridors shall accommodate W2:9 parking in side and /or front yards as allowed in the underlying zoning classification. Lot orientation is toward an internal private drive, resulting in CSAH 75 being adjacent to the side yard of the subject lot, not the rear yard. B. Where a development application covers land located adjacent to an existing parking lot used for similar purposes, a vehicular connection between the parking lots shall be provided wherever possible. This has been provided through the PUD. C. Parking lot landscaping. All development sites shall landscape an area equivalent to fifteen (15) percent of the total area of the required parking lot. The site features 12 landscape islands within required customer /employee parking. This standard is presumed met, however a detailed site analysis could be conducted to confirm. Sian Additional sign standards apply in the Transportation Corridor Overlay Standards: District. A. Free - standing signs shall not be placed nearer than twenty (20) feet from the nearest edge of the transportation corridor right -of- way. Since the property boundary itself is greater than 100' from the edge of the CSAH 75 ROW this standard is met. B. Free - standing signs within the required landscaped greenway shall be designed in a manner complementary to the landscaped greenway. This is not applicable since the viewshed maintenance requirement is 40' from the CSAH 75 ROW and this property is greater than 100' from the ROW. C. Free - standing identification signs shall have a low - profile design not more than eight (8) feet in height and shall be designed to complement and reflect the architecture of the building. Signage approved under PUD. Site Design Additional design standards apply in the Transportation Corridor Overlay Standards: District. A. A forty (40) foot landscaped viewshed is required within the rear yard of the proposed clinic. The 40 foot landscaped buffer is measured beginning at the edge of the CSAH 75 right -of -way nearest to the proposed clinic. As previously identified, the CSAH 75 right of way is separated from the proposed site by the Wobegon Trail /Railway right of way. The site layout exceeds this requirement in distance from highway ROW alone. B. Utility lines, including electric, cable and telephone, to serve the development project shall be installed underground. All junction and access boxes shall be screened. All utility pad fixtures, meter boxes, etc. shall be shown on the site plan and integrated with the architectural elements of the site. This standard is met. C. Trash containers must be enclosed within a fence under Section 51.12 of the Zoning Ordinance. In the Transportation Overlay, W2:10 chain link fences, including those with slats are prohibited when visible from the public right -of -way. A trash enclosure is not visible from CSAH 75. D. Mechanical equipment must be shielded and screened from the public's view and designed to be perceived as an integral part of the building. This standard is met. Bldg Design Additional building design standards apply in the Transportation Corridor Standards: Overlay District. A. All buildings within the property shall be developed as a cohesive entity, ensuring that building placement, architectural treatment, vehicular and pedestrian circulation and other development elements work together functionally and aesthetically. Architectural treatment shall be designed so that all building facades of the same building (whether front, side, or rear) that are visible from the public right -of- way, shall consist of similar architectural treatment in terms of materials, quality, appearance and detail. The approved PUD facilitates the development of all three lots within the Coborns Realty Company Plat as a cohesive entity. B. Clustering. All buildings within the Coborn's Realty PUD are oriented on subject lots in a manner that complement each other and preserve the viewing corridor adjacent to CSAH 75. C. Architectural Appearance /Scale. New buildings shall have generally complex exterior forms, including design components such as windows, doors, and changes in roof and fagade orientation. Large flat expanses of featureless exterior wall shall be avoided. The treatment of buildings shall include vertical architectural treatment at least every 25 -30 feet to break down the scale of the building into smaller components. The proposed building represents a complex exterior form including variations in building height, building depth, and fenestrations (windows & entries). The building's bulk is nicely broken up by the implementation of variations in building wall height and depth and the proper placement of windows and entries. D. Orientation. Building facades and entrances should be oriented in a manner toward the primary means of vehicular access. Primary access is from an internal drive servicing the PUD. E. Architectural details shall continue on all facades visible from the public right -of -way. Architectural details are carried through on all sides visible from CSAH 75. F. All outdoor lighting fixtures shall be down - directed, with light trespass not to exceed 0.5 foot - candles at the property line. All island canopy ceiling fixtures shall be recessed. Whenever possible commercial lighting should be reduced in volume /intensity when said commercial facilities are not open for business. Additional information would be need to completely verify this standard. It is presumed met as there are substantial setbacks. W2:11 c-`11 s I E 170 RD Id gym" + "(sxded (ZTS) 8858 W2-12 600 gym" + "(sxded (ZTS) 8858 W2-12 L4AMPIhA MUNICIPAL DEVELOPMENT GROUP, INC. DATE: March 26, 2008 MEMO TO: Judy Weyrens, City Administrator FROM: Cynthia Smith - Strack, Municipal Development Group RE: CentraCare Clinic Site Plan BACKGROUND CentraCare Health Systems has submitted a site plan for a 12,815 SF medical clinic at the southeast quadrant of the CR 133/Elm Street intersection. The St. Joseph Clinic as proposed is designed to accommodate an additional 9,251 SF future expansion bringing the total square footage of the structure to 22,066. The clinic will be located on the parcel legally described as Lot 2, Block 1 of the Coborns Realty Company plat. The proposed clinic is part of a planned unit development which includes the remaining two lots of Block 1 of the Coborns Realty Company plat. The PUD will accommodate a unified mixed use commercial development consisting of the clinic, a potential supermarket, and a potential multiple tenant commercial facility. The PUD allows for uniform development standards, design synergies, joint parking facilities, and joint stormwater management methodstfacilities. Site plans for the potential supermarket and multiple tenant commercial facility have not been submitted at this time. If/when those developments are proposed for construction, site plan review /approval shall be required. The following are pertinent sections of the Zoning Ordinance applicable to the CentraCare Clinic site plan: Section 52.09 PUD Overlay Section 52.10 Off - Street Parking Section 52.11 Signs Section 52.12 General Performance Standards Section 52.21 Transportation Corridor Overlay Section 52.32 B2 Highway 75 Business District A review of applicable zoning standards follows. This review does not address Building Code or engineering requirements. REVIEW Section 52.09 PUD Overfav The PUD Overlay district allows for the uniform development of one or more lots, tracts, or parcels of land to be developed as a single entity, the plan for which may propose density or intensity transfers, density increases, mixing of land uses, or any combination thereof which may not correspond in lot size, bulk, or type of dwelling or building, density, intensity, lot coverage, parking, required common open space, or other standards to zoning use district requirements that are otherwise applicable to the area in which it is located. W2:13 CentraCare Clinic Site Plan The proposed clinic was subject to PUD Plat review previously. The PUD agreement allows for joint parking facilities, shared access and drive aisles, common design elements, and joint storm water management for all three lots within the Coborns Realty Company Plat. The site plan review constitutes the PUD plan review for this structure. Future structures within the PUD will undergo plan review at the time construction is eminent. Section 52.32 B2 Hiphwav 75 Business District Section 52.09, PUD Overlay is superimposed on the underlying zoning classification. In this case the underlying zoning classification is the B2 Highway 75 Business District. Proposed Use: The proposed use, a medical clinic, is permitted use in the underlying zoning district and, therefore, allowed under the PUD overlay. Performance The PUD overlay allows for density transfers from one location within the Standards: PUD to another; consequently lot sizes and widths may be less than those required in the underlying zoning district. Lot width and size standards are not applicable to this development. It is noted the proposed lot exceeds both lot width and lot size requirements within the underlying zoning classification. Under the PUD overlay, setback requirements within the underlying zoning classification must be achieved. Required setbacks for the subject parcel are: front yard — 20 feet; side yard — 10 feet; and, rear yard — 10 feet. The proposed structure fronts on Elm Street and is illustrated with a front yard setback of 160 feet; side yard setbacks of 90 and 100 feet (including expansion); and, a rear yard setback of 20 feet. [The proposed structure conforms to setback requirements.] Building heights under the PUD overlay revert to the underlying zoning classification. The maximum height in the B2 Highway 75 Commercial District is three (3) stories or forty (40) feet whichever is less. Although exterior profiles are included in the application packet, neither a scale or a written notation as to building elevation is included in the application. The facility is proposed to be a single story; therefore presumably the height will not exceed forty (40) feet. [Owner Representative has Indicated that the building will be under 20' in height and when the second story is constructed the building will not exceed 36' meeting the Ordinance requirements] Maximum structural coverage in the B2 Highway 75 zone is limited to sixty percent (60 %) of the lot area. The PUD overlay allows for variation in structure coverage if approved by the City. The proposed structure (including future expansion) totals 22,066 sf; the lot area totals 163,756 sf. Therefore, structural coverage proposed is 13.4 percent of the lot area, well below the maximum allowed. [The proposed project conforms to maximum structural coverage standards.] Parking: The PUD overlay defers to the underlying zoning district and off -street parking standards included in Section 52.10 of the Zoning Ordinance, except that the City may reduce the required number of parking spaces provided PUD applicants submit information demonstrating a reduced need for parking. The applicable PUD agreement allows for joint parking facilities within the PUD Plat but requires applicants provide evidence that enough parking exists at the time of approval of site plans and common ownership documents allow for joint parking and drive aisles. In addition CentraCare Clinic Site Plan W2:14 the PUD agreement requires employees be required to park in areas as designated on the site plan. Section 52.10 (Off- Street Parking) requires medical clinics provide one (1) space for every 250 feet of floor area. Floor area is defined as the gross floor area used for services to the public including areas occupied for fixtures and equipment used for display or sale of merchandise, less ten (10) percent. It is noted the proposed clinic floor plan identifies several areas for employee offices, storage, and cleaning totaling 3/130 sf (full build out), this square footage can be deducted from the building area as per the definition of floor area. The following calculations determine the amount of parking required. Total Bdg SF 22,068 Minus 3,130 Offices storage, etc. Equals 18,936 Adousted SF Minus 1,89410% deduction E uals 17,042 Net SF applicable Ord. Standard 110 sl Per stall R wired stalls 155 Without adjustment for joint use, the required amount of parking spaces for the proposed development is 155. The site plan illustrates 208 parking stalls. The proposed amount of parking stalls exceeds ordinance requirements. Again, it is noted the PUD agreement allows for joint parking in the future if/when additional structures are constructed. Loading: The PUD overlay defers to the underlying zoning district and off - street loading requirements included in Section 52.10 of the Zoning Ordinance. Section 52.10 (Off - Street Parking) requires loading berths in connection with any structure exceeding 5,000 sf in area that requires the receipt or distribution of materials or merchandise by trucks or similar vehicles. The floor plan and the site plan sheets submitted with the subject application do not include provisions for loading berths. The clinic will not take receipt or distribution of materials or merchandise by semi - trucks or similar vehicles. The Ordinance standard for loading Is not applicable to this project. Buildinq The proposed clinic is subject to building design and exterior material Exterior: standards under this Section (52.32) as well as those included in Section 52.21 (Transportation Corridor Overlay). When in conflict the most restrictive standards prevail. The B -2 Highway Commercial District requires fifty percent (50 %) of all four walls of principal structures not including windows and doors consist of materials comparable to: face brick, natural stone, glass, stucco, aluminum lapsiding, cut block, and decorative concrete block. Section 52.21 (Transportation Corridor Overlay) of the Zoning Ordinance, simply requires building materials be typical of those prevalent in commercial areas, including, but not limited to, stucco, brick, W2:15 CentraCare Clinic Site Plan architectural block, decorative masonry, non - reflective glass and similar materials. The building is proposed to be a steel frame structure finished with cultured stone, pre - manufactured stucco panels and aluminum composite panels. Steel frame structures are allowed within the B2 District provided a concrete block or poured concrete complete perimeter foundation with frost footings extending a minimum of eight (8) inches above the final grade. Foundation details have not been included in the application. [The owner representative has indicated that the foundation will be insulated formed concrete meeting the requirements. Therefore the proposed structure meets the requirements of the Zoning Ordinance relating to building type and exterior finish materials.] Screening: Section 52.32 (132 District) of the Zoning Ordinance requires screening of HVAC equipment and garbage storage areas. The site plan does not illustrate the proposed location of HVAC equipment and illustrates a dumpster positioned south of the proposed employee parking area. The site plan doesn't include detail regarding proposed dumpster enclosure. [The owner representative has indicated that the HVAC will be located on the top of the building and will be screened with metal louver meeting the Ordinance requirements.] Li htin : Section 52.32 requires lighting be hooded and not directly positioned so as to trespass onto CSAH 75 or areas exterior to the development. The PUD agreement requires light trespass not exceed one candle foot at the centerline of an adjacent boulevard. The application includes information regarding proposed luminaries but the site plan does not illustrate proposed location thereof. [The Lighting plan as submitted meets the Ordinance requirements.] Curbing Section 52.32 (132 District) requires installation of high -back curbing for all drive and parking areas. The site plan illustrates curbing adjacent to drive aisles and parking areas. It is noted storm water infiltration structures could impact curbing adjacent to landscape medians internal to the parking lot. [This standard appears to be met; however, additional discussion may be needed.] Landscaoina: Section 52.32 requires a unified landscaping scheme for the proposed development. The PUD agreement requires review of landscaping plans at the time of site plan approval. The proposed clinic site includes a unified landscaping plan which is discussed further later in this report. Section 52.21 Transportation Corridor Overlay District Section 52.21, Transportation Corridor Overlay District is superimposed on the underlying zoning classification (132 Highway 75 Business District). Section 52.21 is intended to enhance the visual appearance of the corridor and to protect and promote the appearance, character, and economic values along the corridor and the surrounding neighborhoods. The district is furthermore intended to maintain the long -term function of arterial and collector roadways. Additional Within the Transportation Corridor Overlay, all buildings must maintain Setback: a minimum setback of forty (40) feet from the CSAH 75 right -of -way. The proposed structure fronts on Elm Street making the rear yard adjacent to CSAH 75. The proposed structure is setback 20 feet from the property line. The property does not abut CSAH 75 right of way, but rather the CentraCare Clinic Site Plan W2:16 Wobegon TraiVMnDOT Railway corridor. The trail corridor right of way exceeds twenty feet in width. [Therefore proposed structure setback greater than 40' from the CSAH 75 ROW meaning the request conforms to setback requirements under Section 52.21 of the Zoning Ordinance.] Parking Additional parking lot standards apply within the Transportation Corridor Standards: Overlay, said standards are in addition to those required under Section 52.10 of the Zoning Ordinance. Specifically, A. Parking areas shall be designed and located so as to have minimal visual impact along transportation corridors. Lots with rear -yards abutting transportation corridors shall accommodate parking in side and /or front yards as allowed in the underlying zoning classification. Lot orientation is toward Elm Street resulting in CSAH 75 being adjacent to the rear yard of the subject lot. Therefore, the parking lot must meet the requirements of the underlying zoning classification and Section 52.10 of the Zoning Ordinance. [The request conforms to this standard.] B. Where a development application covers land located adjacent to an existing parking lot used for similar purposes, a vehicular connection between the parking lots shall be provided wherever possible. For development applications adjacent to vacant properties, the site shall be designed and constructed to provide for a future connection. [The PUD conforms to this standard] in that the clinic parking is intended to be connected with future parking areas in Lot 1 and Lot 3 of the Coboms Realty Company Plat. The required connection as allowed for on the clinic site plan will be from the northeast portion of the parking lot which has a median without landscaping which will be removed to provide joint access. C. Parking lot landscaping. All development sites shall landscape an area equivalent to fifteen (15) percent of the total area of the required parking lot. Said required landscaping shall be employed within the subject parking lot and adjacent to walkways within and leading to /from the subject parking lot. The site plan illustrates landscaping featuring: (1) a vegetative planting strip adjacent to the rear lot line and the western exterior of the PUD highlighted by 15 Honey Locust trees; (2) landscaped boulevard /parking lot medians featuring manicured lawn, mulch and ten Autumn Maple trees; and, (3) a vegetative strip adjacent to the employee parking area and a bicycle trail. [The proposed site plan meets the requirements of this section; however, when expanded the parking lot will need to include additional vegetative islands (i.e. replace the two concrete islands near building front with vegetation). This provision will be placed in the Development Agreement for future Improvements. ] Sin Additional sign standards apply in the Transportation Corridor Overlay Standards: District. CentraCare Clinic Site Plan W2:17 A. Free - standing signs shall not be placed nearer than twenty (20) feet from the nearest edge of the transportation corridor right -of- way. One freestanding sign located near the intersection or CR 133 and Elm Street is illustrated on the site plan. The sign is well over twenty feet from the edge of the CSAH 75 right of way. The site plan conforms to this requirement. B. Free - standing signs within the required landscaped greenway shall be designed in a manner complementary to the landscaped greenway. The sign is not situated within a landscaped greenway. C. Free - standing identification signs shall have a low- profile design not more than eight (8) feet in height and shall be designed to complement and reflect the architecture of the building. [While a sign has been illustrated on the site plan, the only approval at this time Is the location of the sign. The owner will provide separate sign detail before construction and the sign will conform to the Ordinance requirements.] Site Design Additional design standards apply in the Transportation Corridor Overlay Standards: District. A. A forty (40) foot landscaped viewshed is required within the rear yard of the proposed clinic. The 40 foot landscaped buffer is measured beginning at the edge of the CSAH 75 right -of -way nearest to the proposed clinic. As previously identified, the CSAH 75 right of way is separated from the proposed site by the Wobegon Trail /Railway right of way. The site plan includes a 20 foot landscaped strip in the rear yard, in addition, the trail corridor right of way exceeds twenty feet in width. Therefore a greater than forty (40) foot viewshed has bee preserved. B. Utility lines, including electric, cable and telephone, to serve the development project shall be installed underground. All junction and access boxes shall be screened. All utility pad fixtures, meter boxes, etc. shall be shown on the site plan and integrated with the architectural elements of the site. [The owner representative has indicated that all the lines will be underground and the access boxes will be screened with living material]. C. Trash containers must be enclosed within a fence under Section 51.12 of the Zoning Ordinance. In the Transportation Overlay, chain link fences, including those with slats are prohibited when visible from the public right -of -way. The proposed trash enclosure will be visible from CSAH 75. [The owner representative has indicated that the receptacles will be screened with a rock panel.] D. Mechanical equipment must be shielded and screened from the public's view and designed to be perceived as an integral part of the building. [As stated above, the equipment will be located on the roof and screened as per Ordinance.] Bldg Design Additional building design standards apply in the Transportation Corridor CentraCare Clinic Site Plan W2:18 Standards: Overlay District. A. All buildings within the property shall be developed as a cohesive entity, ensuring that building placement, architectural treatment, vehicular and pedestrian circulation and other development elements work together functionally and aesthetically. Architectural treatment shall be designed so that all building facades of the same building (whether front, side, or rear) that are visible from the public right -of -- way, shall consist of similar architectural treatment in terms of materials, quality, appearance and detail. The approved PUD facilitates the development of all three lots within the Coboms Realty Company Plat as a cohesive entity. The clinic parking has been designed to accommodate additional development on lots one and three of the Plat. The applicant should be directed to work with other property owners to develop a master sign plan which would help assure signage patterns work together functionally and aesthetically. The initial building placement as illustrated on the preliminary PUD plat results in a cohesive entity. Architectural treatments for additional site development will be examined in conjunction with site plan review; however, future development will be expected to compliment the approved clinic structure. The proposed clinic meets this standard. B. Clustering. The Coborns Realty Company plat has been developed as a PUD allowing clustering and cohesive design. Buildings shall be arranged in a manner that creates well- defined open space that is viewable from the traveled portion of the corridor. As illustrated in the preliminary PUD plat, the buildings are to be oriented on subject lots in a manner that complement each other and preserve the viewing corridor adjacent to CSAH 75. The proposed clinic meets this standard. C. Architectural Appearance /Scale. New buildings shall have generally complex exterior forms, including design components such as windows, doors, and changes in roof and facade orientation. Large flat expanses of featureless exterior wall shall be avoided. The treatment of buildings shall include vertical architectural treatment at least every 25 -30 feet to break down the scale of the building into smaller components. The proposed building represents a complex exterior form including variations in building height, building depth, and fenestrations (windows & entries). The building's bulk is nicely broken up by the implementation of variations in building wall height and depth and the proper placement of windows and entries. The proposed clinic meets this standard. D. Orientation. Building facades and entrances should be oriented in a manner toward the primary means of vehicular access. The proposed structure is oriented toward the lot front and access from the proposed parking lot. Access is provided through a covered drive up — drop off which is separated from pedestrian walkways by a high back curb. The proposed clinic meets this standard. E. Architectural details shall continue on all facades visible from the public right -of -way. Architectural details are carried through on all four sides of the proposed structure. Architectural details CentraCare Clinic Site Plan W2:19 and building materials as previously described meet the intent of this Section. F. All outdoor lighting fixtures shall be down - directed, with light trespass not to exceed 0.5 foot - candies at the property line. All island canopy ceiling fixtures shall be recessed. Whenever possible commercial lighting should be reduced in volume /intensity when said commercial facilities are not open for business. [As stated above, the Ordinance requirement is met.] Section 52.10 Off- Street Parking Section 52.10 contains standards for off - street parking within commercial districts, including the B -2 District. # of Required Without adjustment for joint use, the required amount of parking spaces Stalls: for the proposed development clinic is 155. The site plan illustrates 208 parking stalls. The proposed amount of parking stalls exceeds ordinance requirements. Again, it is noted the PUD agreement allows for joint parking in the future if/when additional structures are constructed. Surfacing: Commercial parking lots are required to be surfaced with concrete, bituminous, pavement or paver stones. The site plan illustrates parking stalls and striping but does not illustrate type of surfacing. [The owner representative has indicated that the parking lot will be bituminous surfacing with perimeter curbing as required by the Ordinance.] Curbing: Section 52.10 requires perimeter curbing around the parking lot. The site plan illustrates required curbing. [The owner representative has indicated that the curbing will met the Ordinance requirements.] Circulation: Section 52.10 requires vehicular circulation internal to the parking lot. The site plan illustrates parking will not utilize streets or driveways to support vehicular circulation. The site plan is consistent with this requirement. Dimensions: The site plan does not include parking stall dimensions or a scale. The parking stalls proposed appear to be ten feet wide by 20 feet deep. The minimum required by the zoning ordinance is 9 X 17.5 feet. [The owner representative has indicated that the parking lot dimensions will met the requirements including the bumper overhand requirement.] Other: The City Engineer should review drainage and lighting plans. The Building Official should comment on adequacy of emergency lanes. Section 52.11 SidnaQe Section 52.11 contains standards for commercial signage. Adequate information regarding signage has not been submitted at this time. [Sign detail is not provided at this time. The plan indicates where the sign will be located and the owner will met all the Ordinance requirements. Section 52.12 General Performance Standards Section 52.12 of the Zoning Ordinance contains general standards applicable to all areas within the City. Applicable standards within Section 52.12 relate to fencing and landscaping. However, CentraCare Clinic Site Plan W2:20 fencing standards are more restrictive under the Transportation Corridor Overlay, therefore, those standards (addressed previously) apply. Section 52.12 also requires the lot area remaining after providing for parking, driveways, loading, sidewalks or other requirements shall be planted and maintained in grass, sodding, shrubs or other acceptable vegetation or landscaping techniques. The proposed project meets this standard. W2:21 CentraCare Clinic Site Plan Judy Weyrens From: Cynthia Smith - Strack MDG, Inc. [ cstrack @municipaldevelopmentgroup.com] Sent: Wednesday, April 28, 2010 2:37 PM To: Judy Weyrens Subject: Definition of viewshed Judy, I have another resource book I can check for a definition of 'viewshed'. At this time I'd recommend the following definition for consideration "The natural environment or landscape visible from one or more viewing points along a transportation corridor ". Alternately you could change 'visible' to 'that can be seen' and /or you could delete the 'one or more viewing points along' from the recommended definition. Cynthia Smith - Strack Municipal Development Group, Inc. 888- 7MDG -INC (toll free) 952 - 758 -7399 (Metro) 888 - 763 -4462 (fax) 25562 Willow Lane New Prague, MN 56071 www .municipaldevelopmentgroup.com W2:22