Loading...
HomeMy WebLinkAbout[02-01]Item Number: 1 Cable Connection Configurations MicroLogix 1000 Programmable Controllers to Term inals /OI /PCs MicroLogix Programmable Controllers to Programming Terminals /Operator Interfaces DH -485 MicroLogix RS -232 -C I DH -485 Port 2 1761 - NET -AIC 1784 KR 615x, 618x, Controller 1761 - CBL -AM00 0.45m (1.5 ft) 77 (Belden 3106A or 9842) T53, T60, T70, T71, or IBM 80386 /greater 1761 - CBL -HM02 2.0m (6.5 ft) IBM PC Al or 1761- CBL -PM02 2.0m (6.5 ft) MicroLogix Controller RS -232 -C DH -485 �o2 1761 - NET -AIC 1784 -KTX 615x, 618x, 1761 - CBL -AM00 0.45m (1.5 ft) (Belden 3106A or 9842) T53, T60, or T70, T71, 1761 - CBL -HM02 2.0m (6.5 ft) IBM 80386 /greater or IBM PC Al 1761 - CBL -PM02 Urn (6.5 ft) � MicroLogix RS -232 -C DH 485 DH -485 Controller Port 2 1761 - NET -AIC 1747 -AIC 2 1784 -PCMK 1761 - CBL -AM00 (Belden 3106A 1784 -PCM4 0.45m (1.5 ft) or 9842) 3.06m (10 ft) notebook with PCMCIA or 1761 - CBL -HM02 2.0m(6.5ft) or 1761 - CBL -PM02 2.0m (6.5 ft) With the 1761 - CBL -PM02 cable you need to power the 1761- NET -AIC with an external +24V do power supply. 2 You need to power this AIC with an external +24V do power supply. 20 -24 Allen - Bradley Cable Connection Configurations MicroLogix 1000 Programmable Controllers to Term inals /Ol /PCs MicroLogix Programmable Controllers to Programming Terminals /Operator Interfaces/ Personal Computer /Hand -Held Programmer RS -232 -C MicroLogix 1000 Programmable i Com T70 Controller 1761 - CBL -PM02 2.Om (6.56 ft) Port IBM 80386 /greater or IBM PC XT/AT 2707 NC8 2.Om (6.56 ft) NEC VERSATm E Series Notebook Upload /Download Cable GatewayTm 2000 models 386DX/25, 386DX/33, 486DX/33, 486DX2/50, and 486DX2/66 personal computers MicroLogix 1000 MicroLogix 1000 Programmable Hand -Held Controller 1761- CBL -HM02 2.Om (6.56 ft) Programmer or 2707 -NC11 2.Om (6.56 ft) MicroLogix 1000 MicroView Operator Programmable Controller 2707 -NC9 15m (49.2 ft) Interface or 2707 -NC11 2.Om (6.56 ft) or 1761 - CBL -HM02 2.Om (6.56 ft) MicroLogix 1000 Programmable DTAM Micro Controller 2707 -NC9 1.8m (6 ft) Operator Interface t The connector is at a 90° angle. Allen - Bradley 20 -25 Cable Connection Configurations DTAM Micro or DTAM Plus Operator Interface to Processor DTAM Micro Operator Interface RS -232 -C Gender Adapter (9 -pin female to male) Com Port DTAM Micro 2707 - M232P3 Com Port DTAM Micro 2707 - M232P3 1747 -CP3 3.96m (13 ft) SLC 5/03, 5/04, 5/05 Processors 2707 -NC3 2.43m (8 ft) PLC -5 Processor i IBM 80386 /greater 2707 -NC23 1.83m (6 ft) IBM PC XT /AT 3 To transfer application programs from the DTAM Micro to a personal computer, use the 2707 -NC2 cable. DTAM Micro Operator Interface RS -232 -C Com Port DTAM Micro 2707 - M232P3 Com Port 2707— NC21.8m (6 ft) DTAM Micro 2707 - M232P3 Com Port 2707 -NC1 DTAM Micro 1.98m (6.5ft) 2707- M485P3 2707 -NC10 1.83m (6 ft) 1761 - NET -AIC 1761- CBL -HM02 2m (6.5 ft) DTAM Micro Operator Interface DH -485 1747 -AIC1 (Belden 9842) 1747 -AIC1 0.3m (1 ft) MicroLogix 1000 Microl-ogix 1000 SLC 500 or SLC 5/03 Processor 2707 -NC4 4.57m (15 ft) I PLC -5 Processor 1 Electrical isolation using Link Couplers is required in applications where the distance between the DTAM Micro terminal and the SLC processor is greater than 2 m (6.5 ft). 2 The DTAM Micro RS-485 port supports RS -422 communication with the PLC -5 processor. RS -422 communication is limited by the PLC processor to 19.2k bit/s and a distance of 61 m (200 ft). 20 -26 Allen- Bradley Cable Connection Configurations DTAM Plus OI to Processor or DTAM Module to SLC Processor DTAM Plus Operator Interface to SLC and PLC Processors RS -232 -C Gender Adapter (9 -pin female to male) Com % SLC 5/03, Port SLC -5/04, or 2707 1747 -CP3 3.96m (13 ft) SLC 5/05 DTAM Pluslnterface processor Com Port 2707 DTAM Plus Interface 2707 DTAM Plus Interface Com Port 2707 -NC2 1.8m (6 ft) 2707 DTAM Plus Interface 1' 747 DTAM Module PLC 5 - RS -232 DF1 protocol: 2707 -NC3 2.43 m (8 ft) processor RS -422 protocol: 2707 -NC4 4.57 m (15 ft) DTAM Plus Operator Interface to MicroLogix Processors RS -232 -C 1747 DTAM Module 2707 -NC10 1.83m (6 ft) 1761 - NET -AIC 1761- CBL -HM02 2m (6.5 ft) DTAM Module to SLC Processors DH -485 Network 1 1747 C10 1.83m (6 ft) (ships with 1747 DTAM) 1747 AIC 2 DH -485 (Belden 9842) MicroLogix 1000 1747 AIC 1747 -Cll 0.3m (1 ft) (ships with 1747 -AIC) MicroLogix 1000 fixed SLC 500, SLC 5/01, SLC 5/02, or SLC -5/03 processor SLC 5/03, DH -485 SLC 5/04, or 1747 -AIC 2 1761- NET -AIC SLC 5/05 1747 -C10 1.83m (6 ft) (Belden 9842) 1747 -CP3 3.96m (13 ft) processor (ships with 1747 DTAM) (channel 0) 1 The DH -485 network provides remote communication of up to 1219.2 m (4,000 ft). You can communicate with up to 31 SLC processors, one at a time, using a 1747 -AIC at each node. 2 You need to power this AIC with an external +24V do power supply. 20 -28 Allen - Bradley Cable Connection Configurations MicroView Operator Interface to PC /MicroLogix PLC MicroView Operator Interface to Personal Computer RS -232 -C l MicroView Operator Com I 615x, 618x, Interface POrtj T53, T60, 2707 -NC8 2.Om (6.5 ft) T70, T71, Upload /Download able IBM 80386 /greater IBM PC Al Power supplyl MicroView Operator Interface to MicroLogix PLC F RS -232 -C � MicroLogix 1000 MicroVew Operator Programmable Interface 2707 -NC9 15m (49.2 ft) Controller 2 or 2707 -NC11 2m (6.5 ft) or 1761- CBL -HM02 2m (6.5 ft) 1 When you use a PC to download a program to the MicroView operator interface, you must use an external power supply (cat. no. 2707-PS 120 or 2707- PS220). 2 When the MicroView operator interface is plugged directly into the MicroLogix 1000 processor, the MicroView operator interface gets its power directly from the processor. DeviceView Handheld Configurator to PC /OI DeviceView Handheld Configurator to Personal Computer/Terminal RS -232 -C DeviceView Handheld Com 615x, 618x, Configurator2 Port T53, T60, 2707 -NC8 2.0m (6.5 ft) T70, T71, Upload /Download Cable IBM 80386 /greater IBM PC AT 2 The DeviceView Configurator requires a power supply (cat. no. 2707 -PS220 or 2707- PS120H). Allen - Bradley 20 -29 Cable Connection Configurations DeviceNet Scanners to DeviceNet Adapters Scanners/ Processors DeviceNet Network 1/0 Adapters / Devices 1400 Operator Terminals ; I 1485D Devicel-ink Single 24V do Sensor Personal Computer with PCI bus 1771 -SDN PLC -5 Scanner for PLC chassis , i , Input Interface 1784 -PCD processor PCMCIA Interface Card 1792D Series ArmorBlock MaXum 1/0 11792 Series ArmorBlock 1/0 Blocks PHOTOSWITCH Series 9000 and RightSight Sensors SLC 5/02, 1747 -SDN ' -ADN 57941794 ADN FLEX Integra and SLC 5/03, or scanner for SLC chassis , RediSTATION Operator Interface SLC 5/04 , (2705- T3DN1A42A, -T3DN1 B42A) 1784 -PCIDS ; PCI -bus PC scanner for PCI BUS 1784 - CPCIDS PCI Communication Personal Computer Interface Card ; with PCI bus ' 1756 -DNB Logix5550 Processor Interfaces ' PowerMonitor II Master Module with , 1403 -NDNET Communication Card Panel view 550, 600, 900,1000, and ' 1400 Operator Terminals ; DTAM Plus and DTAM Micro Operator Interfaces Personal Computer with PCI bus 2707 -DNC DeviceView Handheld Configurator 871TM Series Inductive Proximity Sensor i , , 1784 -PCD 802T Series Limit Switch PCMCIA Interface Card 1792D Series ArmorBlock MaXum 1/0 11792 Series ArmorBlock 1/0 Blocks ' 1791 D Series CompactBlock 1/0 -ADN 57941794 ADN FLEX Integra and FLEX 1/0 adapter FLEX 1/0 modules ' PowerMonitor II Master Module with , 1403 -NDNET Communication Card 1203 -GK5, -GU6 SCANport- enabled products: 1305 AC 1336 -GM5, -GM61 drive, 1336 PLUS AC drive, 1336 PLUS II DeviceNet Adapters AC drive, 1336 IMPACT AC drive, 1336 FORCE AC drive, 1336 REGEN package, 1336 SPIDER AC drive, 1394 SERVO, 1397 DC drive, 1557 Medium Voltage AC drive, SMC DIALOG PLUS, SMP SMART Motor Protector, 2364 RGU DC Bus Regenerative front end. Computer with PCMCIA compatibility 160 Series Smart Speed Controller with 160 DN2 DeviceNet Communication Module RS 232 Personal Computer: 1770 -KFD, -KFDG RS -232 Interface + 1761 NET DNI MicroLogix Interface 1761 - CBL -AM00 0.45m (1,5 ft) Controller or 1761- CBL -HM02 2.0m(6.5ft) ControlNet 1788 -CN2DN ControlNet to 855T Stack Lights DeviceNet Linking Device ,—1 ULTRA 100 Drives � 825 Smart Motor Manager 1 The 1336 -GM5, -GM6 work with 1336 PLUS products B Frame and larger. For detailed cabling information, see DeviceNet Product Overview, publication DN -2.5. Allen- Bradley 20 -35 1784 -PCI D ' PCI Communication ; Interface Card Personal Computer with PCI bus ; i , 1784 -PCD PCMCIA Interface Card 1203 -GK5, -GU6 SCANport- enabled products: 1305 AC 1336 -GM5, -GM61 drive, 1336 PLUS AC drive, 1336 PLUS II DeviceNet Adapters AC drive, 1336 IMPACT AC drive, 1336 FORCE AC drive, 1336 REGEN package, 1336 SPIDER AC drive, 1394 SERVO, 1397 DC drive, 1557 Medium Voltage AC drive, SMC DIALOG PLUS, SMP SMART Motor Protector, 2364 RGU DC Bus Regenerative front end. Computer with PCMCIA compatibility 160 Series Smart Speed Controller with 160 DN2 DeviceNet Communication Module RS 232 Personal Computer: 1770 -KFD, -KFDG RS -232 Interface + 1761 NET DNI MicroLogix Interface 1761 - CBL -AM00 0.45m (1,5 ft) Controller or 1761- CBL -HM02 2.0m(6.5ft) ControlNet 1788 -CN2DN ControlNet to 855T Stack Lights DeviceNet Linking Device ,—1 ULTRA 100 Drives � 825 Smart Motor Manager 1 The 1336 -GM5, -GM6 work with 1336 PLUS products B Frame and larger. For detailed cabling information, see DeviceNet Product Overview, publication DN -2.5. Allen- Bradley 20 -35