HomeMy WebLinkAbout[02-04]Operator Interface
PanelView Standard Terminals and Software
Specifications
Display
Type
Size
Replaceable Backlight
Item Number: 4
PanelView 1000 Grayscale and Color and PanelView 1400 Color C11. C E U�
PanelView 1000 PanelView 1000 PanelView 1400
Grayscale Display Color Display Color CRT
--T(TFT)
Elecboluminescent Color Active Matrix Thin Film Transistor Color CRT (SVGA)
(W x H) 211 x 158 mm (W x H) 211 x 158 mm (W x H) 255 x 191 mm
(8.3 x 6.2 in) (8.3 x 6.2 in) (10.0 x 7.5 in)
Not Applicable — emissive display Field replaceable backlight Not Applicable
Touch Cells 384
Function Keys 16 (F1— F16) 21 (F1— F21)
Real -Time Clock
Application Memory
Electrical
Battery- backed clock timestamps critical data
1 M byte Flash
(application screens + text + bitmaps)
Communication Port
DeviceNet, ControlNet, DH +, Remote IIO, DH -485, RS-232 (DH -485 protocol), DF1, PROFIBUS, Modbus
RS-232 Printer Port
1200, 2400, 9600,19200k bills
Power Requirements
AC: 85 to 264V ac; DC: 18-32V do
AC: 85 to 264V ac; DC: Not Applicable
Power Consumption
AC: 100 VA maximum; DC: 40 Watts
max (1.74A 0 24V dc)
AC: 70 VA maximum; DC: 27 Watts
max (1.1A 0 24V dc)
AC: 200 VA max; DC: Not Applicable
Programming
PanelBuilder32 (Windows - based) software
Environmental
Operating Temperature
0 to 55 °C (32 to 131 ° F)
Storage Temperature
—25 to 70 °C ( -13 to 1587) -40 to 85 °C (-40 to 185 °F)
Humidity
5 to 950/6 (without condensation) 0 0 to 30°C (32 to 86 ° F)
Ratings
NEMA Type 12,13,4X (indoor only), IP54, IP65
Certifications
UL,CSA Approved; Class I Div 2, Groups A, B, C, D certified
CE marked; Demko
UL, cUL approved; CE marked
weight
Cat. No. Keypad Terminal 2
Cat. No. Keypad & Touch Terminal
Keypad
3.3 kg (7.2 lbs.)
3.7 kg (8.2 lbs.)
20.3 kg (44.75 lbs.)
Touch Screen
3.2 kg (7.0 lbs.)
3.6 kg (7.9 lbs.)
19.6 kg (43.2 lbs.)
Dimensions
PanelView 300 Monochrome, RS -232 (DF1) Communication t
fffl- K3A17L1
Keypad
(H x W x D)
(H x W x D)
Cat. No. Keypad & Touch Terminal
282 x 423 x 112 mm
355 x 483 x 394 mm
Not Applicable
(11 x 17 x 5 in)
(13.97 x 19.0 x 15.53 in)
Touch Screen
(H x W x D)
(H x W x D)
Cat. No. Keypad & Touch Terminal 234
282 x 370 x 112 mm
355 x 441 x 394 mm
2711 -135A2
(11 x 15 x 5 in)
(13.97 x 17.37 x 15.53 in)
Ordering Information
PanelView 300 Monochrome Terminals
Cat. No. Keypad Terminal 2
Cat. No. Keypad & Touch Terminal
PanelView 300 Monochrome, DH -485 Communication Ports t
2711- K3A2L1
Not Applicable
PanelView 300 Monochrome, RS-232 (DH -485) Communication Port
2711- K3A5L1
Not Applicable
PanelView 300 Monochrome, DeviceNet Communication & RS -232 Printer Port
2711- K3A10L1
Not Applicable
PanelView 300 Monochrome, RS -232 (DF1) Communication t
fffl- K3A17L1
Not Applicable
PanelView 300 Micro Monochrome Terminals — Keypad Only
Cat. No. Keypad Terminal 2
Cat. No. Keypad & Touch Terminal
PanelView 300 Micro, RS-232 (DF1) Communication Port (8-pin mini -DIN) t
2711- M3A18L1
Not Applicable
PanelView 300 Micro, RS -232 (DH -485) Communication Port (8-pin mini -DIN) t
2711- M3A191.1
Not Applicable
PanelView 550 Monochrome Terminals
Cat. No. Keypad Terminal 234
Cat. No. Keypad & Touch Terminal 234
PanelView 550 Monochrome, DH-485 Communication Ports 1
2711 -K5A2
2711 -135A2
Pane[View 550 Monochrome, DH-485 Communication & RS-232 Printer Port
2711 -K5A3
2711 -B5A3
PanelView 550 Monochrome, RS -232 (DH -485) Communication Port t
2711 -K5A5
2711 -B5A5
PanelView 550 Monochrome, RS-232 (DH -485) Communication & RS -232 Port t
2711 -K5A9
2711 -135A9
PanelView 550 Monochrome, Remote VO Communication & RS-232 Printer Port
2711 -K5A1
2711 -65A1
PanelView 550 Monochrome, DH+ Communication & RS -232 Printer Port
2711 -K5A8
2711 -135A8
19 -12 Allen- Bradley
Chapter 7
Installing the PV300 Terminal
Chapter Objectives This chapter shows how to install the PanelView 300 terminal and
covers:
• hazardous locations
• enclosures
• required tools
• mounting dimensions
• clearances
• cutout dimensions
• installing the PV300 terminal in a panel
Hazardous Locations See the nameplate label on terminal for hazardous location
certifications.
Explosion Hazard
• Substitution of components may impair suitability
for Class I, Division 2.
A • Do not disconnect equipment unless power has
been switched off and area is known to be
non - hazardous.
• Do not connect or disconnect components unless
power has been switched off.
• All wiring must comply with N.E.C. article
501 -4(b).
The PV300 terminals have an operating temperature code of T4
(maximum operating temperature of 135° C or 275° F). Do not install
these terminals in environments where atmospheric gases have
ignition temperatures less than 135° C (275° F).
Publication 2711- UM014C -EN -P
7 -2 Installing the PV300 Terminal
Enclosures Mount the PV300 terminal in a panel or enclosure to protect the
internal circuitry. The terminal meets NEMA Type 12/13 and 4X
(indoor use) ratings only when mounted in a panel or enclosure with
the equivalent rating.
Allow enough space within the enclosure for adequate ventilation.
Consider heat produced by other devices in the enclosure. The
ambient temperature around the terminals must be between 00 and
55° C (321 and 131° F).
Make provisions to access the back panel of the terminal for wiring,
maintenance, installing a memory card and troubleshooting.
Required Tools Other than the tools required to make the PV300 panel cutout, the
tools required for installation are:
• 7 mm (M4) deep well socket wrench or nut driver
• small slotted screwdriver
• torque wrench (in / lbs)
Publication 2711- UM014C -EN -P
Mounting Dimensions
Cutout Dimensions
Installing the PV300 Terminal 7 -3
The illustration below shows mounting dimensions for the PV300
keypad terminals.
0000
197 mm
0000 (7.76 in)
aoo 000
ooa o
000
1 00
�140mm_�
(5.53 in)
Top View
ri
69mm 62 mm
(2.73 in) =UH i
Us e the full size template shipped with the PV300 terminal to mark
the cutout dimensions. Below is a reduce size cutout.
120 am
4.71 in)
109 mm
4.29 in) —►
0
U
140 am
5.53 in)
17 am
6.99 in)
0
A 4.5 am via
(0.178 in)
Publication 2711 -UM01 4C-EN-P
7 -4 Installing the PV300 Terminal
Clearances When installing the PV300 terminal, allow space for mounting, air
flow, maintenance, memory card and legend strip installation.
Leave 64 mm (2.5 in)
for Mounting and Air Flow
Publication 2711- UM014C -EN -P
Side, Top and Bottom Clearances
Back Clearance
Leave 64 mm (2.5 in)
for Mounting and Air Flow
46
69 mm
mm
(2.73 i� n) 5.3 in)
p
(8.5 in ) is required with
rd to
card retainer. Allows 6mm (.25) in
clearance) to insert and remove a
M
memory card with the memory card
Retainer
retainer.
J Card
L
Installing the PV300 Terminal 7 -5
Installing the PV300 in a To install the PV300 terminal in a panel:
Panel
• Disconnect all electrical power from the panel
before making the cutout.
• Make sure the area around the panel cutout is
clear.
• Do not allow metal cuttings to enter any
components that may already be installed in the
panel.
• Failure to follow this warning may result in
personal injury or damage to the panel
components.
1. Cut an opening in the panel using the panel cutout provided
with the terminal. Remove any sharp edges or burrs.
2. Make sure the terminal sealing gasket is properly positioned on
the terminal as shown below. This gasket forms a compression
type seal. Do not use sealing compounds.
Legend Strip
Sealing Gasket
3. Verify that the end of the legend strip is fully inserted and does
not interfere with the sealing gasket.
4. Place the terminal in the panel cutout.
5. Verify that the opening is the proper size to clear the bezel and
to allow the gasket to contact the panel.
Publication 2711- UM014C -EN -P
7 -6 Installing the PV300 Terminal
6. Install the self - locking nuts hand tight.
a. ^ *� ^ +�� installation label
—Self- locking nuts
(4 used, 6 provided)
Mounting Studs (2 left, 2 right)
7. Alternately tighten the self - locking nuts until the terminal is held
firmly against the panel. Tighten nuts to a torque of 10
inch - pounds. Do not over - tighten.
Mounting nuts must be tightened to a torque of
10 inch - pounds to provide a proper seal and to
prevent potential damage to the terminal.
Allen - Bradley assumes no responsibility for
4A water or chemical damage to the terminal or
other equipment within the enclosure because
of improper installation.
8: Remove the protective installation label covering the top vents
of the terminal.
Failure to remove the protective installation
label covering the top vents could result in
overheating and damage to the terminal.
Publication 2711- UM014C -EN -P