Loading...
HomeMy WebLinkAbout[02-04]Operator Interface PanelView Standard Terminals and Software Specifications Display Type Size Replaceable Backlight Item Number: 4 PanelView 1000 Grayscale and Color and PanelView 1400 Color C11. C E U� PanelView 1000 PanelView 1000 PanelView 1400 Grayscale Display Color Display Color CRT --T(TFT) Elecboluminescent Color Active Matrix Thin Film Transistor Color CRT (SVGA) (W x H) 211 x 158 mm (W x H) 211 x 158 mm (W x H) 255 x 191 mm (8.3 x 6.2 in) (8.3 x 6.2 in) (10.0 x 7.5 in) Not Applicable — emissive display Field replaceable backlight Not Applicable Touch Cells 384 Function Keys 16 (F1— F16) 21 (F1— F21) Real -Time Clock Application Memory Electrical Battery- backed clock timestamps critical data 1 M byte Flash (application screens + text + bitmaps) Communication Port DeviceNet, ControlNet, DH +, Remote IIO, DH -485, RS-232 (DH -485 protocol), DF1, PROFIBUS, Modbus RS-232 Printer Port 1200, 2400, 9600,19200k bills Power Requirements AC: 85 to 264V ac; DC: 18-32V do AC: 85 to 264V ac; DC: Not Applicable Power Consumption AC: 100 VA maximum; DC: 40 Watts max (1.74A 0 24V dc) AC: 70 VA maximum; DC: 27 Watts max (1.1A 0 24V dc) AC: 200 VA max; DC: Not Applicable Programming PanelBuilder32 (Windows - based) software Environmental Operating Temperature 0 to 55 °C (32 to 131 ° F) Storage Temperature —25 to 70 °C ( -13 to 1587) -40 to 85 °C (-40 to 185 °F) Humidity 5 to 950/6 (without condensation) 0 0 to 30°C (32 to 86 ° F) Ratings NEMA Type 12,13,4X (indoor only), IP54, IP65 Certifications UL,CSA Approved; Class I Div 2, Groups A, B, C, D certified CE marked; Demko UL, cUL approved; CE marked weight Cat. No. Keypad Terminal 2 Cat. No. Keypad & Touch Terminal Keypad 3.3 kg (7.2 lbs.) 3.7 kg (8.2 lbs.) 20.3 kg (44.75 lbs.) Touch Screen 3.2 kg (7.0 lbs.) 3.6 kg (7.9 lbs.) 19.6 kg (43.2 lbs.) Dimensions PanelView 300 Monochrome, RS -232 (DF1) Communication t fffl- K3A17L1 Keypad (H x W x D) (H x W x D) Cat. No. Keypad & Touch Terminal 282 x 423 x 112 mm 355 x 483 x 394 mm Not Applicable (11 x 17 x 5 in) (13.97 x 19.0 x 15.53 in) Touch Screen (H x W x D) (H x W x D) Cat. No. Keypad & Touch Terminal 234 282 x 370 x 112 mm 355 x 441 x 394 mm 2711 -135A2 (11 x 15 x 5 in) (13.97 x 17.37 x 15.53 in) Ordering Information PanelView 300 Monochrome Terminals Cat. No. Keypad Terminal 2 Cat. No. Keypad & Touch Terminal PanelView 300 Monochrome, DH -485 Communication Ports t 2711- K3A2L1 Not Applicable PanelView 300 Monochrome, RS-232 (DH -485) Communication Port 2711- K3A5L1 Not Applicable PanelView 300 Monochrome, DeviceNet Communication & RS -232 Printer Port 2711- K3A10L1 Not Applicable PanelView 300 Monochrome, RS -232 (DF1) Communication t fffl- K3A17L1 Not Applicable PanelView 300 Micro Monochrome Terminals — Keypad Only Cat. No. Keypad Terminal 2 Cat. No. Keypad & Touch Terminal PanelView 300 Micro, RS-232 (DF1) Communication Port (8-pin mini -DIN) t 2711- M3A18L1 Not Applicable PanelView 300 Micro, RS -232 (DH -485) Communication Port (8-pin mini -DIN) t 2711- M3A191.1 Not Applicable PanelView 550 Monochrome Terminals Cat. No. Keypad Terminal 234 Cat. No. Keypad & Touch Terminal 234 PanelView 550 Monochrome, DH-485 Communication Ports 1 2711 -K5A2 2711 -135A2 Pane[View 550 Monochrome, DH-485 Communication & RS-232 Printer Port 2711 -K5A3 2711 -B5A3 PanelView 550 Monochrome, RS -232 (DH -485) Communication Port t 2711 -K5A5 2711 -B5A5 PanelView 550 Monochrome, RS-232 (DH -485) Communication & RS -232 Port t 2711 -K5A9 2711 -135A9 PanelView 550 Monochrome, Remote VO Communication & RS-232 Printer Port 2711 -K5A1 2711 -65A1 PanelView 550 Monochrome, DH+ Communication & RS -232 Printer Port 2711 -K5A8 2711 -135A8 19 -12 Allen- Bradley Chapter 7 Installing the PV300 Terminal Chapter Objectives This chapter shows how to install the PanelView 300 terminal and covers: • hazardous locations • enclosures • required tools • mounting dimensions • clearances • cutout dimensions • installing the PV300 terminal in a panel Hazardous Locations See the nameplate label on terminal for hazardous location certifications. Explosion Hazard • Substitution of components may impair suitability for Class I, Division 2. A • Do not disconnect equipment unless power has been switched off and area is known to be non - hazardous. • Do not connect or disconnect components unless power has been switched off. • All wiring must comply with N.E.C. article 501 -4(b). The PV300 terminals have an operating temperature code of T4 (maximum operating temperature of 135° C or 275° F). Do not install these terminals in environments where atmospheric gases have ignition temperatures less than 135° C (275° F). Publication 2711- UM014C -EN -P 7 -2 Installing the PV300 Terminal Enclosures Mount the PV300 terminal in a panel or enclosure to protect the internal circuitry. The terminal meets NEMA Type 12/13 and 4X (indoor use) ratings only when mounted in a panel or enclosure with the equivalent rating. Allow enough space within the enclosure for adequate ventilation. Consider heat produced by other devices in the enclosure. The ambient temperature around the terminals must be between 00 and 55° C (321 and 131° F). Make provisions to access the back panel of the terminal for wiring, maintenance, installing a memory card and troubleshooting. Required Tools Other than the tools required to make the PV300 panel cutout, the tools required for installation are: • 7 mm (M4) deep well socket wrench or nut driver • small slotted screwdriver • torque wrench (in / lbs) Publication 2711- UM014C -EN -P Mounting Dimensions Cutout Dimensions Installing the PV300 Terminal 7 -3 The illustration below shows mounting dimensions for the PV300 keypad terminals. 0000 197 mm 0000 (7.76 in) aoo 000 ooa o 000 1 00 �140mm_� (5.53 in) Top View ri 69mm 62 mm (2.73 in) =UH i Us e the full size template shipped with the PV300 terminal to mark the cutout dimensions. Below is a reduce size cutout. 120 am 4.71 in) 109 mm 4.29 in) —► 0 U 140 am 5.53 in) 17 am 6.99 in) 0 A 4.5 am via (0.178 in) Publication 2711 -UM01 4C-EN-P 7 -4 Installing the PV300 Terminal Clearances When installing the PV300 terminal, allow space for mounting, air flow, maintenance, memory card and legend strip installation. Leave 64 mm (2.5 in) for Mounting and Air Flow Publication 2711- UM014C -EN -P Side, Top and Bottom Clearances Back Clearance Leave 64 mm (2.5 in) for Mounting and Air Flow 46 69 mm mm (2.73 i� n) 5.3 in) p (8.5 in ) is required with rd to card retainer. Allows 6mm (.25) in clearance) to insert and remove a M memory card with the memory card Retainer retainer. J Card L Installing the PV300 Terminal 7 -5 Installing the PV300 in a To install the PV300 terminal in a panel: Panel • Disconnect all electrical power from the panel before making the cutout. • Make sure the area around the panel cutout is clear. • Do not allow metal cuttings to enter any components that may already be installed in the panel. • Failure to follow this warning may result in personal injury or damage to the panel components. 1. Cut an opening in the panel using the panel cutout provided with the terminal. Remove any sharp edges or burrs. 2. Make sure the terminal sealing gasket is properly positioned on the terminal as shown below. This gasket forms a compression type seal. Do not use sealing compounds. Legend Strip Sealing Gasket 3. Verify that the end of the legend strip is fully inserted and does not interfere with the sealing gasket. 4. Place the terminal in the panel cutout. 5. Verify that the opening is the proper size to clear the bezel and to allow the gasket to contact the panel. Publication 2711- UM014C -EN -P 7 -6 Installing the PV300 Terminal 6. Install the self - locking nuts hand tight. a. ^ *� ^ +�� installation label —Self- locking nuts (4 used, 6 provided) Mounting Studs (2 left, 2 right) 7. Alternately tighten the self - locking nuts until the terminal is held firmly against the panel. Tighten nuts to a torque of 10 inch - pounds. Do not over - tighten. Mounting nuts must be tightened to a torque of 10 inch - pounds to provide a proper seal and to prevent potential damage to the terminal. Allen - Bradley assumes no responsibility for 4A water or chemical damage to the terminal or other equipment within the enclosure because of improper installation. 8: Remove the protective installation label covering the top vents of the terminal. Failure to remove the protective installation label covering the top vents could result in overheating and damage to the terminal. Publication 2711- UM014C -EN -P