Loading...
HomeMy WebLinkAbout[08c] Government Center - Generator Council Agenda Item 8c urry 01 S-ri MEETING DATE: September 19, 2016 AGENDA ITEM: Administrator Report—Government Center SUBMITTED BY: Administration PREVIOUS COUNCIL ACTION: The City Council approved the construction of the Government Center and originally made provisions for a portable generator. BACKGROUND INFORMATION: The project is over 50% complete and the project still has a contingency of over S 200,000. Most of the changes to date have been minor with the largest price change the addition of the sign. Since we are proposing to use the Government Center as the hub in the event of an emergency the staff is requesting the placement of a permanent generator. The proposed generator has been sized to accommodate the facility. The summary of price adjustments is included with the Treasurers Report along with the financial summary. BUDGET IMPACT: S up to S 60,000 ATTACHMENTS: Request for Council Action Price Proposal REQUESTED COUNCIL ACTION: Authorize the purchase and installation of a generator for the Government Center. OFS4 aECnW PMME=M-1658 4807 Heatherwood RUL(5701=4276 Box 1252 ELECTRICAL CONTRACTORS INC. COLD Sv+W4aELECTMCSEirvM FAX E32°'�63 St.Cloud,MN 5631 TO: R.A.Morton Date: 9/8/2016 ATTN: Paul PROJECT: ST.Joseph Government Center SUBJECT: Added Diesel Generator We herewith submit our proposal and description for changes requested as follows: DESCRIPTION OF CHANGE: Added Caterpillar Diesel Generator total$59,592.12 Gen pad by others Fuel By City AMOUNT: Subcontractor with markup $ Material $ 66,267.41 Labor $ 3,324.71 Bond $ - Total $ 59,592.12 Deduct from total$-3,400 for Cummins This proposal will be valid until: 30 days Normal working unless noted otherwise. Additional Comments: See attached breakdown. If you have any questions,please feel free to contact us. Very truly yours, Adam Kempenich Design Electric,Inc. DESCRIPTION QTY JUNITPRICE PER I AMOUNT UNIT PER I AMOUNT 10awg 280 $ 143.70 1000 $ 40.24 5.5 1000 1.54 12awg 140 $ 96.59 1000 $ 13.52 4.5 1000 0.63 14awg 560 $ 65.61 1000 $ 36.74 4 1000 2.24 4SQ BOX 2 $ 2.25 1 $ 4.50 0.3 1 0.6 4"PVC FIT 13 $3.79 1 $ 49.27 0.25 1 3.25 Backhoe trench 20 5.5 11 110 8 1001 1.6 Backfill 20 4.5 1 90 8 100 1.6 ground rod and clamp 2 25.5 1 51 0.3 1 0.6 Relocate conduit stack 1 1 $ - 7.5 1 7.50 2"PVC 60 $62.25 100 $ 37.35 3.5 100 2.1 2"PVC FIT 9 $0.65 1 $ 5.85 1 0 2"PVC 90 3 $1.86 1 $ 5.58 0.3 1 0.9 breaker 2 1 $ - 0.15 1 0.30 1/2 FLEX 20 $ 65.00 100 $ 13.00 3.5 1001 0.7 motor cnn 2" 3 49.36 1 148.08 0.9 11 2.7 4"flex 10 794.96 100 79.496 6 1001 0.6 4 flex conn 4 190.72 1 762.88 0.15 1 0.6 off load/crane 1 $ 750.00 1 $ 750.00 2.5 1 2.50 ATS startup test check out 1 1 $ - 4 1 4.00 Gen layout 1 1 $ 2 1 2.00 Startup and training en 1 1 $ 2 1 2.00 Gen Design 1 1 $ - 2.5 1 2.50 CAT Generator Quote 1 $45,545.00 1 $ 45,545.00 1 1/0 ground wire 120 $ 1,386.00 1000 $ 166.32 16 1000 1.92 Gen conn. Cab return 1 $ 3,100.00 1 $ 3,100.00 1 - en level 2 sound cab 1 $ 1,075.00 1 $ 1,075.00 1 4hr load bank 1 $ 1,335.00 1 $ 1,335.00 1 remote annunciator 1 $ 420.00 1 $ 420.00 1 1 $ 1 1 $ 1 Clean up 1 I 1 $ 01 1 Testing Check out 1 1 $ 1 adjustment 11 1 1 $ - 1 MAT $ 47,638.83 LABOR 42.38 Material $ 47,638.83 Mark up 10% $ 4,763.88 Material w/Mark up $ 52,402.71 TAX 7.38% $ 3,864.70 Material subtotal $ 56,267.41 Subcontractor with markup Inspection fee $ - Hours Rate Labor 42.38 $ 71.00 $ 3,008.98 Labor Premium Hours Adder $ 35.00 $ - Foreman Labor 4.24 $ 74.50 $ 315.73 Subtotal $ 59,592.12 Bond cost 0% $ - Subtotal $ 59,592.12 Total Cost $ 599592.12 Proposal by Date: September 8, 2016 Z I E G L E R ► Proposal No. EPG222461 r PoweSystems 8050 State Highway 101 Shakopee, MN 55379 952-887-4535 To. Design Electric Re: Caterpillar Standby Generator Attn: Adam Kempenich St Joseph Government Center WE PROPOSE TO FURNISH INA CCORDANCE WITH THE FOLLOWING SPECIFICATIONS,TERMS AND CONDITIONS QUANTITY One (1) new CATERPILLAR Diesel Generator Set, UL Listed Certified Package In Weatherproof Enclosure mounted on top of 24 hour Dual Wall Base Fuel Tank, MODEL D200-2 3 phase, Tier 3 emissions certified, RATING 200kW 3 phase standby power VOLTAGE 120/208, 3 phase, 60 HZ, 1800 RPM, CIRCUIT BREAKER One (1) 800 amp SWITCHGEAR By others INSTALLATION By others TOTAL EQUIPMENT PRICE $ 45,545 .00- OPTIONAL 5,545 .00*OPTIONAL ADDERS Provide Level 2 Sound Attenuated insulated enclosure in place of standard Weatherproof Enclosure TOTAL PRICE ADDER $ 1,075 .00* Provide Four(4) hour load bank test on generator at site after installation (fuel by others) TOTAL PRICE ADDER $ 1,335 .00* Provide Remote Annunciator, NFPAI 10 with alarms, shipped loose TOTAL PRICE ADDER $ 420 .00* *Please refer to the attached Bill of Material. *Price does not include state or local sales and/or use tax. APPROXIMATE SHIPPING DATE 8-10 weeks after approval drawings F O.B Jobsite on truck TERMS: Net 20 days THIS PROPOSAL SUBJECT TO ALL PROVISIONS OF THE CONTRACT AND WARRANTY ONREVERSE SIDE ACCEPTED: Respectfully submitted, ZIEGLER INC. By P&tAA Ec kt�rwiaw Doug Eckerman, Sales Engineer By Subject to approval by APPROVED: ZIEGLER INC. Its By BILL OF MATERIAL EPG222461 -1 - EMERGENCY STANDBY GENERATOR SET, RATED 20OKW 3 PHASE STANDBY @ 120/208 VOLT, 60 HERTZ, 1800 RPM ENGINE SPECIFICATIONS 6 Cylinder In-line engine 7.1 liter displacement Oil filter, spin-on type Electrical governor Radiator cooling system, blower fan Water pump 12V DC starting system Jacket water heater, 120 volt, 1500 watt Alternator, 55 ampere, 12 VDC Fuel system, diesel STANDARD ENGINE SAFETY FEATURES Shutdowns Fail to start/ Overcrank High coolant temperature Low lube oil pressure Overspeed Low coolant level Spare alarm/shutdown channel w/LED annunciation GENERATOR SPECIFICATIONS Class H insulation, rotor and stator, single bearing design, upgraded from std generator Flexible coupling Brushless Excitation Solid-state regulator, +/- 0.5%regulation Mainline circuit breaker, 3 pole, 800 amps, 208 volt EMCP 4.2 Series control panel features: Run/off/auto switch Remote signals/contacts from panel: Terminals for remote emergency stop Common fault alarm signal Start/Stop volt free control Panel lights Audible alarm Modbus Isolated Data Link RS 485 Communications built in Three (3)-attempt start timer(adjustable) Lamp test pushbutton AC instrumentation for volts, amps, frequency Seven (7)position voltmeter phase selector switch Four(4)position ammeter phase selector switch Red lockdown stop pushbutton ENCLOSURE Standard weatherproof enclosure Lockable doors, Color, white BILL OF MATERIAL EPG222461 -2 - ANCILLARY EQUIPMENT Battery charger, 10 ampere, float type, dual rate Battery, with battery rack and cables Exhaust silencer, critical grade, shipped loose Voltage Adjust Potentiometer Volt free contacts for Generator set run and alarm LTL Listed base mounted fuel tank, dual wall, 24 hour capacity SWITCHGEAR By others PROJECT MANAGEMENT SERVICES Submittal drawings Dimensional drawings Electrical schematics Product specifications Prototype testing Production testing Technical assistance - coordinated through project manager Jobsite testing Operation and maintenance manual Engine, generator Warranty, Two (2) years Training of owner's personnel COMMENTS AND CLARIFICATIONS Crane to offload NOT included Fuel is NOT included Installation is NOT included NOTES Ziegler limits the scope of supply for this quotation to the equipment and services listed. Equipment not listed is assumed to be provided by others. Ziegler cannot provide air emission permits for customers. We will provide emission information on the Caterpillar engine to the owner to aid in the permitting process. Orders are subject to re-stocking charges if cancelled after release for production. State and local permits for fire, air, fuel tanks or building permits are not included and provided by others Terms: • Extension of contract beyond term must be at the mutual agreement of the parties. • Ziegler Inc. shall not be liable for consequential damages or damages beyond our control. • This quotation is subject to availability at time of order • Orders are subject to re-stocking charges if cancelled after release for production. • Customer is responsible for adequate site conditions and security. • Customer is responsible for scheduled maintenance and fuel costs. • Customer must provide adequate insurance to cover equipment damage or loss. • Price(s) do not include state or local sales and/or use taxes. • Quotation is valid for 90 days. Power Generation Our - working Quotation Cummins NPower, LLC 1600 Buerkle Road White Bear Lake MN 55110 United States Direct: 651-286-2124 September 8, 2016 Project Name: St Joseph Government Center Quotation: 36352562 Thank you for your inquiry. We are pleased to quote as follows: USD Description Diesel Genset: 60Hz-200kW U.S. EPA, Stationary Emergency Application 200DSGAE Genset-Diesel,60Hz,200kW 1 Duty Rating-Standby Power Listing-UL 2200 Emissions Certification, EPA, Tier 3, NSPS Cl Stationary Emergency Enclosure-Steel,Sound Att,Level 2,w/Exhaust System Voltage-120/208,3 Phase,Wye,4 Wire Alternator-60 Hz, 12 Lead, Lower Broad Range, 105C Generator Set Control-PowerCommand 2.2 Exciter/Regulator-Torque Match Engine Governor-Electronic, Isochronous Only Display Language-English Control Mounting-Left Facing Relays-Genset Status, User Configured Stop Switch-Emergency Signals-Auxiliary, 8 Inputs/8 Outputs Heater-Alternator, 120 Volt AC CB or EB or TB-Left Only CirBrkr-800A,Left,3P,600/415V,SS RMS,80%UL/IEC CB or EB or TB-Bottom Entry, Left Shunttrip-12vdc,Single Circuit Breaker Listing, ULC-S601-07 Wind Rating-150 MPH,Steel Housing Fuel Tank-Dual Wall Subset, 24 Hour Capacity Separator-Fuel/Water Warning-Low Fuel Level Warning-Fuel in Rupture Basin Engine Starter- 12 VDC Motor Battery Charging Alternator-Normal Output Engine Cooling-High Ambient Air Temperature Shutdown-Low Coolant Level Extension-Engine Coolant Drain Engine Coolant-50% Antifreeze, 50% Water Mixture Coolant Heater-120 Volt Ac, Single Phase Engine Air Cleaner-Heavy Duty Engine Oil Genset Warranty- Base Literature-English Packing-Skid, Poly Bag Rack-Battery Extension-Oil Drain Common Parts Listing Product Revision - E Freight to site Startup 2- 12volt batteries Grand Total $4 , Not included in above: Sales tax, Offloading, Verbal Deduct of-10% _ $ 42,750.00 Fuel, Special testing, Engineering, Permits Annunciator ---------------Add $ 500.00 4-Hour Load test---------Add $ 1,200.00 Submitted by